{"products":[{"id":"slayer-steam-ep","slug":"slayer-steam-ep","name":"Slayer STEAM EP","brand":"Slayer","brand_id":"brand-017","category":"semi_automatic","use_segment":"commercial","summary":"Research Slayer STEAM EP using manufacturer sources. Check the selected reference configuration and confirm availability, installation and service in your market.","settings":["Coffee service"],"status":"availability_to_confirm","versions":["Manufacturer overview","2GR single phase","2GR three phase","3GR single phase","3GR three phase"],"variants":[{"version":"Manufacturer overview","region":"Reference","source_scope":"observed official page locale; configuration scope retained","specs":{"boiler_architecture":"multi_boiler","PID":true,"pressure_flow_control":"0–4 seconds pre-wet/pause before 9-bar extraction","dimensions_scope":"excludes overhanging portafilters, actuators and cup rails"},"field_evidence":{"boiler_architecture":{"verification_status":"verified","source_url":"https://slayerespresso.com/product/steam-ep/","checked_at":"2026-10-03","source_section":"Technical specifications / features","source_scope":"observed official page locale; configuration scope retained","claim_type":"manufacturer_claim","region":"Reference"},"PID":{"verification_status":"verified","source_url":"https://slayerespresso.com/product/steam-ep/","checked_at":"2026-10-03","source_section":"Technical specifications / features","source_scope":"observed official page locale; configuration scope retained","claim_type":"manufacturer_claim","region":"Reference"},"pressure_flow_control":{"verification_status":"verified","source_url":"https://slayerespresso.com/product/steam-ep/","checked_at":"2026-10-03","source_section":"Technical specifications / features","source_scope":"observed official page locale; configuration scope retained","claim_type":"manufacturer_claim","region":"Reference"},"dimensions_scope":{"verification_status":"verified","source_url":"https://slayerespresso.com/product/steam-ep/","checked_at":"2026-10-03","source_section":"Technical specifications / features","source_scope":"observed official page locale; configuration scope retained","claim_type":"manufacturer_claim","region":"Reference"}}},{"version":"2GR single phase","region":"Reference","source_scope":"official page locale","specs":{"width_mm":890,"depth_mm":710,"height_mm":432,"weight_kg":100,"power_W":{"min":4700,"max":5600},"voltage":"220–240 V","frequency_Hz":[50,60],"group_count":2,"steam_boiler_L":7.4},"field_evidence":{"width_mm":{"verification_status":"verified","source_url":"https://slayerespresso.com/product/steam-ep/","checked_at":"2026-10-03","source_section":"Technical specifications / 2GR single phase","source_scope":"official page locale","claim_type":"manufacturer_claim","region":"Reference"},"depth_mm":{"verification_status":"verified","source_url":"https://slayerespresso.com/product/steam-ep/","checked_at":"2026-10-03","source_section":"Technical specifications / 2GR single phase","source_scope":"official page locale","claim_type":"manufacturer_claim","region":"Reference"},"height_mm":{"verification_status":"verified","source_url":"https://slayerespresso.com/product/steam-ep/","checked_at":"2026-10-03","source_section":"Technical specifications / 2GR single phase","source_scope":"official page locale","claim_type":"manufacturer_claim","region":"Reference"},"weight_kg":{"verification_status":"verified","source_url":"https://slayerespresso.com/product/steam-ep/","checked_at":"2026-10-03","source_section":"Technical specifications / 2GR single phase","source_scope":"official page locale","claim_type":"manufacturer_claim","region":"Reference"},"power_W":{"verification_status":"verified","source_url":"https://slayerespresso.com/product/steam-ep/","checked_at":"2026-10-03","source_section":"Technical specifications / 2GR single phase","source_scope":"official page locale","claim_type":"manufacturer_claim","region":"Reference"},"voltage":{"verification_status":"verified","source_url":"https://slayerespresso.com/product/steam-ep/","checked_at":"2026-10-03","source_section":"Technical specifications / 2GR single phase","source_scope":"official page locale","claim_type":"manufacturer_claim","region":"Reference"},"frequency_Hz":{"verification_status":"verified","source_url":"https://slayerespresso.com/product/steam-ep/","checked_at":"2026-10-03","source_section":"Technical specifications / 2GR single phase","source_scope":"official page locale","claim_type":"manufacturer_claim","region":"Reference"},"group_count":{"verification_status":"verified","source_url":"https://slayerespresso.com/product/steam-ep/","checked_at":"2026-10-03","source_section":"Technical specifications / 2GR single phase","source_scope":"official page locale","claim_type":"manufacturer_claim","region":"Reference"},"steam_boiler_L":{"verification_status":"verified","source_url":"https://slayerespresso.com/product/steam-ep/","checked_at":"2026-10-03","source_section":"Technical specifications / 2GR single phase","source_scope":"official page locale","claim_type":"manufacturer_claim","region":"Reference"}}},{"version":"2GR three phase","region":"Reference","source_scope":"official page locale","specs":{"width_mm":890,"depth_mm":710,"height_mm":432,"weight_kg":100,"power_W":{"min":4900,"max":5700},"voltage":"380–415 V","frequency_Hz":[50,60],"group_count":2,"steam_boiler_L":7.4},"field_evidence":{"width_mm":{"verification_status":"verified","source_url":"https://slayerespresso.com/product/steam-ep/","checked_at":"2026-10-03","source_section":"Technical specifications / 2GR three phase","source_scope":"official page locale","claim_type":"manufacturer_claim","region":"Reference"},"depth_mm":{"verification_status":"verified","source_url":"https://slayerespresso.com/product/steam-ep/","checked_at":"2026-10-03","source_section":"Technical specifications / 2GR three phase","source_scope":"official page locale","claim_type":"manufacturer_claim","region":"Reference"},"height_mm":{"verification_status":"verified","source_url":"https://slayerespresso.com/product/steam-ep/","checked_at":"2026-10-03","source_section":"Technical specifications / 2GR three phase","source_scope":"official page locale","claim_type":"manufacturer_claim","region":"Reference"},"weight_kg":{"verification_status":"verified","source_url":"https://slayerespresso.com/product/steam-ep/","checked_at":"2026-10-03","source_section":"Technical specifications / 2GR three phase","source_scope":"official page locale","claim_type":"manufacturer_claim","region":"Reference"},"power_W":{"verification_status":"verified","source_url":"https://slayerespresso.com/product/steam-ep/","checked_at":"2026-10-03","source_section":"Technical specifications / 2GR three phase","source_scope":"official page locale","claim_type":"manufacturer_claim","region":"Reference"},"voltage":{"verification_status":"verified","source_url":"https://slayerespresso.com/product/steam-ep/","checked_at":"2026-10-03","source_section":"Technical specifications / 2GR three phase","source_scope":"official page locale","claim_type":"manufacturer_claim","region":"Reference"},"frequency_Hz":{"verification_status":"verified","source_url":"https://slayerespresso.com/product/steam-ep/","checked_at":"2026-10-03","source_section":"Technical specifications / 2GR three phase","source_scope":"official page locale","claim_type":"manufacturer_claim","region":"Reference"},"group_count":{"verification_status":"verified","source_url":"https://slayerespresso.com/product/steam-ep/","checked_at":"2026-10-03","source_section":"Technical specifications / 2GR three phase","source_scope":"official page locale","claim_type":"manufacturer_claim","region":"Reference"},"steam_boiler_L":{"verification_status":"verified","source_url":"https://slayerespresso.com/product/steam-ep/","checked_at":"2026-10-03","source_section":"Technical specifications / 2GR three phase","source_scope":"official page locale","claim_type":"manufacturer_claim","region":"Reference"}}},{"version":"3GR single phase","region":"Reference","source_scope":"official page locale","specs":{"width_mm":1130,"depth_mm":710,"height_mm":432,"weight_kg":139,"power_W":{"min":6300,"max":7600},"voltage":"220–240 V","frequency_Hz":[50,60],"group_count":3,"steam_boiler_L":12},"field_evidence":{"width_mm":{"verification_status":"verified","source_url":"https://slayerespresso.com/product/steam-ep/","checked_at":"2026-10-03","source_section":"Technical specifications / 3GR single phase","source_scope":"official page locale","claim_type":"manufacturer_claim","region":"Reference"},"depth_mm":{"verification_status":"verified","source_url":"https://slayerespresso.com/product/steam-ep/","checked_at":"2026-10-03","source_section":"Technical specifications / 3GR single phase","source_scope":"official page locale","claim_type":"manufacturer_claim","region":"Reference"},"height_mm":{"verification_status":"verified","source_url":"https://slayerespresso.com/product/steam-ep/","checked_at":"2026-10-03","source_section":"Technical specifications / 3GR single phase","source_scope":"official page locale","claim_type":"manufacturer_claim","region":"Reference"},"weight_kg":{"verification_status":"verified","source_url":"https://slayerespresso.com/product/steam-ep/","checked_at":"2026-10-03","source_section":"Technical specifications / 3GR single phase","source_scope":"official page locale","claim_type":"manufacturer_claim","region":"Reference"},"power_W":{"verification_status":"verified","source_url":"https://slayerespresso.com/product/steam-ep/","checked_at":"2026-10-03","source_section":"Technical specifications / 3GR single phase","source_scope":"official page locale","claim_type":"manufacturer_claim","region":"Reference"},"voltage":{"verification_status":"verified","source_url":"https://slayerespresso.com/product/steam-ep/","checked_at":"2026-10-03","source_section":"Technical specifications / 3GR single phase","source_scope":"official page locale","claim_type":"manufacturer_claim","region":"Reference"},"frequency_Hz":{"verification_status":"verified","source_url":"https://slayerespresso.com/product/steam-ep/","checked_at":"2026-10-03","source_section":"Technical specifications / 3GR single phase","source_scope":"official page locale","claim_type":"manufacturer_claim","region":"Reference"},"group_count":{"verification_status":"verified","source_url":"https://slayerespresso.com/product/steam-ep/","checked_at":"2026-10-03","source_section":"Technical specifications / 3GR single phase","source_scope":"official page locale","claim_type":"manufacturer_claim","region":"Reference"},"steam_boiler_L":{"verification_status":"verified","source_url":"https://slayerespresso.com/product/steam-ep/","checked_at":"2026-10-03","source_section":"Technical specifications / 3GR single phase","source_scope":"official page locale","claim_type":"manufacturer_claim","region":"Reference"}}},{"version":"3GR three phase","region":"Reference","source_scope":"official page locale","specs":{"width_mm":1130,"depth_mm":710,"height_mm":432,"weight_kg":139,"power_W":{"min":5800,"max":6500},"voltage":"380–415 V","frequency_Hz":[50,60],"group_count":3,"steam_boiler_L":12},"field_evidence":{"width_mm":{"verification_status":"verified","source_url":"https://slayerespresso.com/product/steam-ep/","checked_at":"2026-10-03","source_section":"Technical specifications / 3GR three phase","source_scope":"official page locale","claim_type":"manufacturer_claim","region":"Reference"},"depth_mm":{"verification_status":"verified","source_url":"https://slayerespresso.com/product/steam-ep/","checked_at":"2026-10-03","source_section":"Technical specifications / 3GR three phase","source_scope":"official page locale","claim_type":"manufacturer_claim","region":"Reference"},"height_mm":{"verification_status":"verified","source_url":"https://slayerespresso.com/product/steam-ep/","checked_at":"2026-10-03","source_section":"Technical specifications / 3GR three phase","source_scope":"official page locale","claim_type":"manufacturer_claim","region":"Reference"},"weight_kg":{"verification_status":"verified","source_url":"https://slayerespresso.com/product/steam-ep/","checked_at":"2026-10-03","source_section":"Technical specifications / 3GR three phase","source_scope":"official page locale","claim_type":"manufacturer_claim","region":"Reference"},"power_W":{"verification_status":"verified","source_url":"https://slayerespresso.com/product/steam-ep/","checked_at":"2026-10-03","source_section":"Technical specifications / 3GR three phase","source_scope":"official page locale","claim_type":"manufacturer_claim","region":"Reference"},"voltage":{"verification_status":"verified","source_url":"https://slayerespresso.com/product/steam-ep/","checked_at":"2026-10-03","source_section":"Technical specifications / 3GR three phase","source_scope":"official page locale","claim_type":"manufacturer_claim","region":"Reference"},"frequency_Hz":{"verification_status":"verified","source_url":"https://slayerespresso.com/product/steam-ep/","checked_at":"2026-10-03","source_section":"Technical specifications / 3GR three phase","source_scope":"official page locale","claim_type":"manufacturer_claim","region":"Reference"},"group_count":{"verification_status":"verified","source_url":"https://slayerespresso.com/product/steam-ep/","checked_at":"2026-10-03","source_section":"Technical specifications / 3GR three phase","source_scope":"official page locale","claim_type":"manufacturer_claim","region":"Reference"},"steam_boiler_L":{"verification_status":"verified","source_url":"https://slayerespresso.com/product/steam-ep/","checked_at":"2026-10-03","source_section":"Technical specifications / 3GR three phase","source_scope":"official page locale","claim_type":"manufacturer_claim","region":"Reference"}}}],"image":null,"image_kind":null,"image_alt":null,"source_url":"https://slayerespresso.com/product/steam-ep/","source_checked_at":"2026-10-03","research_product_id":"brand-017-steam-ep","research_snapshot_id":"20261004T000921Z","reference_scope":"observed official page locale; configuration scope retained","is_update":false,"specs":{},"field_evidence":{},"brand_verification_status":"verified","research_image_rights_status":null,"source_scope":"product_or_catalog","source_links":[],"record_level":"partial_specs","record_kind":"model_family","classification_status":"catalog_context_needs_direct_product_review","missing_reason":"Public official specifications extracted; null fields remain unpublished, unreviewed or configuration-dependent.","category_verification_status":"catalog_context","use_segment_evidence":{"verification_status":"verified","source_url":"https://slayerespresso.com/product/steam-ep/","source_section":"Barista service workflow","checked_at":"2026-10-05","claim_type":"manufacturer_positioning"},"preferred_version":"2GR single phase","catalog_supplement_checked_at":"2026-10-05"}],"fullProductIds":["slayer-steam-ep"]}